ONLINE TENSION SENSOR, Tension Monitoring System
Tension Sensor TSL
December 13, 2019
ONLINE TENSION SENSOR, Tension Monitoring System
Tension Sensor TSB1
December 13, 2019

Tension Sensor TSF

6 Tension ranges available
from 0 – 50 cN up to 0 – 5000 cN

Stationary electronic tension sensor for measuring sensitive materials as optical fibres, technical fibres etc.

Large, smooth running guide rollers with 70 mm groove diameter for minimized material deflection. The outer rollers can be moved downward, in case of non-measurements

Tension sensor for quick and easy mounting

Description

Special Features

• Tension sensor TSF with integrated measuring amplifier and high accuracy of 1 % FS

• Large bending radius for gentle handling of sensitive material

• Smooth running, V-grooved guide rollers, ball-bearing mounted with 70 mm Ø

• The outer rollers can be moved downwards to minimize contact in case of non-measurements

• Various output signals are available:
– analog: 0 – 1 V DC (standard), 0 – 10 V DC (optional)
– current: 4 – 20 mA (optional)
– analog DMS: mV/V (optional)

• Easy installation, even afterwards, on existing machines

• Easy calibration to customized material by operator – zero and gain calibration is required

• Tension sensor with mechanical overload protection

• Measuring principle – load cell with high quality strain gauge bridge

Note: a wide range of custom designed models as well modifications are available on request. Please contact us with your demand!

Standard Features

• Tension sensor TSF with rugged aluminum housing

• Required power supply +15…24 V DC (regulated)

• Certificate of Compliance with the order 2.1 according EN 10204 is included

• Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report

Available Models 

Model Tension Range
Measuring Head Width*
SCHMIDT Calibration Material**
TSF-100 0 – 100 cN 270 mm PA: 0.12 mm Ø
TSF-200 0 – 200 cN 270 mm PA: 0.12 mm Ø
TSF-500 0 – 500 cN 270 mm PA: 0.20 mm Ø
TSF-1000 0 – 1000 cN 270 mm PA: 0.30 mm Ø
TSF-2000 0 – 2000 cN 270 mm PA: 0.50 mm Ø
TSF-5000 0 – 5000 cN 270 mm PA: 0.80 mm Ø
Other tension ranges and measuring head widths available on request.
Other measuring units available, such as g.
* Outer distance between outside guide rollers
** Suitable for 95 % of applications PA = Polyamide Monofilament
Catalog